Loop Thermosyphon
Category: Electronic Equipment Key Module & Parts
Exhibitor: KOLINK INTERNATIONAL CORPORATION
Booth No: N421
Characteristic
The main components of a Loop Thermosyphon are the evaporator, condenser, vapor pipeline, and liquid return pipeline. Using an internal vacuum and low-pressure state, when the heat source contacts the evaporator, the fluid is heated and vaporized. The vapor then moves to the condenser, where the heat is carried away by external fans. Once the temperature drops, the gas condenses back into liquid and flows through the liquid return pipeline to the evaporator, completing one cycle.
The advantage of this system is its ability to transfer heat over long distances without needing an external pump. However, its performance can be affected by the direction of gravity, which can influence its efficiency.